Decorator PIR Occupancy Sensor 150 Degree 4 Wire Ivory

Product Code: LFU-HMOS-I
Availability:
In Stock
Price: $17.14 Ex Tax: $15.83
This product has a minimum quantity of 20

Decorator PIR Occupancy Sensor 150 Degree 4 Wire Ivory

Price Offer: 10/pk Price $158.33/pk

Minimum Order: 2 packs (20 Units) $316.67 (Limited Offer till Stock)

 

Description: The passive infrared sensors work by detecting the difference between heat emitted from the human body in motion and the background space. The sensor switch can turn a load on and hold it as long as the sensor detects occupancy. After no motion is detected for the set time delay, the load turned off automatically. This product has one relay (equal to Single Pole Switch), also includes adjustable Ambient Light Level.

Features:

 Turn lights ON/OFF automatically (Occupancy Mode)
 Manual ON / automatically OFF (Vacancy Mode)
 Time delay is adjustable from 15 seconds (test mode) to 30 minutes
 Neutral wire required
 Zero Crossing for long relay life
 Adjustable sensitivity settings
 Light level is adjustable
 Standard decorator wall plate included

Specifications:
Voltage ……………………………………..……………………..…...............................120 Vac, 60 Hz
Incadescent ………………………………………….…………………………...............................500W
Fluorescent …………………………………………..…………….………...............................…500 VA
Motor …………………………………………………………………….…...............................….1/8 HP
Time delay ………………………………………………….…...............................…15 Sec to 30 Mins
Operation temperating …………………………………..………...............................…..32 F to 131 F

*Coverage Area:

 

Installation & wiring:


1. Connect lead wires as wiring diagram (see Figure 2): Black lead to hot wire, red lead to load wire, white lead to neutral wire, green lead to ground wire.

2. Device “TOP” upward.

3. Gently position wires in wall box, attach sensor switch to the box.

4. Restore power at circuit breaker or fuse, wait one minute.

5. Locate the toggle switch on both sides of the top cover to perform test and adjustment.

Wiring diagram:

Changing the color of your switch

Your switch ships with top cover attached. It is convenient for users to change the top cover. Please proceed as follows:

Push down top cover to release Line up tabs and push up to attach

Testing & Code Compliance
 UL LISTE D
 California Title 24

Adj ustment:

Band switch prescription:

Mode Position Description Function of ON/OFF button
VAC Upper side Vacancy Mode: Manual On only,
Automatic Off after set time delay.
Manually push On/Off the load.
OCC Lower side Occupancy Mode: Automatic On, Automatic Off after set time delay. Manually push On/Off the load.

Time delay setting:

Default position 15 Seconds (Test mode)
Adjustable 15 Seconds 15 Seconds 15 Seconds

Ambient light(Default setting):

Notice: If the ambient light level is too high, more than the default setting the load may not automatic turned ON. If turning ON is desired,
cover the sensor lens with one hand for 2 seconds, the light is going to turn ON.

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad            Good

Enter the code in the box below: